Easy to use, powerful, compact and robust – Spectrum Two™ is the FT-IR spectrometer of choice for everyone, everywhere. With fully integrated, robust universal sampling for trouble-free measurements and portability options, Spectrum Two is ideal for use in both laboratory and remote testing environments. Ideally suited to everyday analysis, you can confidently perform fast, accurate IR analysis and assure the quality of your materials across a wide range of applications. Choose the Spectrum Two + that combines a powerful industrial-grade touch screen with cloud connectivity to offer you maximum productivity.
false falsePlease enter valid quantity
Please log in to add favorites.
NULL OR EMPTY CART
IR for Everyone, Everywhere
Spectrum Two™ breaks ground in operational simplicity, combining superb performance with low maintenance design. True laboratory performance IR for everyday analysis is possible for everyone, everywhere.
The Spectrum Two is suitable for a wide range of applications and can be configured to your needs regarding the level of performance desired to meet the demands of your daily IR analyses. See the configurations table below for all available instrument options.
Spectrum Two FT-IR spectrometers feature:
Additional features that allow for consistent performance of this system include:
For Every Application
PerkinElmer recognizes that every application is different. The result is a complete solution to provide the fastest assurance of the quality of your materials, regardless of the application. Some of the industry applications that the Spectrum Two is designed to accommodate include:
For these specific applications, we offer various analysis systems and application pack add-ons. Spectrum Two is designed to function with a variety of “plug-and-go” sampling accessories to enhance the versatility of the instrument. We offer a range of UATR, HATR, Diffuse Reflectance, and Specular Reflectance accessories for use with the Spectrum Two system.
Results Matter
The Spectrum 10™ software supplied with your instrument enables you to control the instrument and to manipulate the spectra that you collect. The spectrometers can operate in ratio, single-beam, or interferogram mode.
From material and contaminant identification to quantitative analysis, the comprehensive Spectrum 10 software suite allows you to focus on what matters most – results. Designed for busy industrial or academic laboratories, this comprehensive FT-IR software package facilitates data collection, processing, and results generation. The software enables users without scientific training to generate infrared spectra from a sample and validate them against reference spectra in minutes, or even seconds. For regulated industries that demand secure IR quality testing, Spectrum 10 ES™ software is available. Spectrum 10 ES includes the comprehensive features of Spectrum 10 and encompasses user access control, audit trailing, data security, and data integrity to ensure secure analyses to meet the technical demands of 21 CFR Part 11 compliance.
Collaborate From The Cloud
Spectrum 10 software with NetPlus™ cloud connectivity offers new sharing and collaborative tools that allow you to access data from any device, any time, from anywhere, and selectively distribute and download data and methods through the built-in publishing tool.
IR Ready to Go
The compact and robust design of the Spectrum Two means that the instrument can be easily transferred between environments. The simple user-installation and fast warm-up time means that the instrument can be set up quickly. The wide range of sampling accessories available can help your analysis move out of the laboratory. With optional features such as wireless connectivity to enable portable PC control, or the Portability Pack featuring a carrying case, battery pack, and 12V car auxiliary port adaptor, the Spectrum Two is ready to go where you go.
21 CFR Part 11 Compatible | Yes |
---|---|
Depth | 30.0 cm |
Detector Type | LiTaO3 |
Height | 21.0 cm |
Model Name | Spectrum Two FT-IR Spectrometer (LiTaO3 Detector) |
Operating Range | 5 - 45 °C |
Portable | Yes |
Product Brand Name | Spectrum Two |
Warranty | 1 year |
Wave Length | 8 |
Wave Length Range | 8,300 – 350 cm-1 |
Weight | 13.0 kg |
Width | 45.0 cm |
Detector Type | Windows | APV/AVI? | Software | Part Number |
---|---|---|---|---|
LiTaO3 | KBr | No | Spectrum 10 | L160000A |
LiTaO3 | KBr | No | Spectrum 10 ES | L160000I |
LiTaO3 | KBr | Yes | Spectrum 10 | L160000B |
LiTaO3 | KBr | Yes | Spectrum 10 ES | L160000J |
LiTaO3 | ZnSe | No | Spectrum 10 | L160000C |
LiTaO3 | ZnSe | No | Spectrum 10 ES | L160000K |
LiTaO3 | ZnSe | Yes | Spectrum 10 | L160000D |
LiTaO3 | ZnSe | Yes | Spectrum 10 ES | L160000L |
In the midst of the COVID-19 outbreak, key hygiene supplies have become in high demand so much so that there are now critical supply shortfalls. One of the most important of these is alcohol-based hand sanitizer. To cope with this shortfall, the food and drug administration (FDA) has produced a guid ...
A Rapid, Green, FT-IR Method for Testing Hydrocarbon Contamination
Application Note, Adulterant Screen, Detection Olive Oil, Attenuated Total Reflectance, ATR, FT-IR, Infrared, Spectrum 2, Spectrum Two, SIMCA, PCA, PLS, Spectrum Touch
The intensifying global emphasis on developing sustainable fuel supplies has led to increasing use of fuels derived from biological sources. In this note we show that the Spectrum Two™ FT-IR spectrometer (Figure 1) can be used to develop a quantitative method with sufficient sensitivity to meet the ...
Condition monitoring of lubricants with FTIR spectroscopy is a useful diagnostic tool that can help us to determine whether a lubricant is fit for purpose during its service life. However, analyzing lubricating grease is different to other less viscous lubricants due to the physical characteristics ...
Biodiesel fuels are often blended compositions of diesel fuel and esterified soybean oils, rapeseed oils, or other potential vegetable oils as well as fats. The physical and combustion properties of these biofuels have allowed them to achieve similar performance to diesel fuel. However, there are se ...
Ethylene-vinyl acetate (EVA) has been a material of key importance as an encapsulant of photovoltaic (PV) modules used in the solar energy industry. Given that the encapsulant has such a vital role in maintaining the function of the PV module, it is important to understand and characterize the vario ...
Ethylene-vinyl acetate (EVA) has been a material of key importance as an encapsulant of photovoltaic (PV) modules used in the solar energy industry. EVA has many favorable characteristics as an encapsulant material. It is important to understand and characterize the various failure modes of differen ...
Building specifications for the interior wall finish require the application of a vapor barrier rated primer followed by the normal decorative paint/top coat. Some architects and developers of condominium housing projects have started using a rated vapor barrier primer/paint to replace the tradition ...
Solid-state batteries (SSBs) are quickly becoming more popular as the industry looks to improve upon rechargeable battery performance and safety. These are batteries which use a solidstate electrolyte in place of the more conventional liquid electrolyte. Hyphenated techniques allow the user to not o ...
Application Note, Glycerol, diethylene glycol, DEG, Infrared Spectroscopy, Compare, Adulterant Screen, Spectrum 10, Spectrum 10 ES, Near Infrared Spectroscopy, IR, NIR, spectra of standards, pharmacopoeia standards, Spectrum Two, UATR, Diamond ATR
IR spectroscopy is an ideal method for quantifying benzene at the concentration levels required, and there are several standard methods for this measurement, all of which utilize the distinctive C–H out-of-plane deformation band at around 673 cm-1. While this band is characteristic of benzene, tolue ...
Transformer insulating oil is often exposed to high temperatures due to the high voltage electrical applications for which it is commonly used. As a result, insulating oil degrades over time, reducing its ability to act as an insulator and possibly leading to equipment failure. 2,6-di-tert-butyl-p-c ...
This note examines the Determination of Hydrocarbons in Environmental Samples with Spectrum Two FT-IR.
This work shows an on-site, rapid and low-cost technique for the accurate measurement of flower potency. FT-NIR spectroscopy provides rich information regarding the chemical composition of cannabis flower. When combined with chemometrics, the FT-NIR offers unparalleled speed and simplicity that cann ...
There are ongoing attempts to improve the storage stability of mRNA vaccines by converting them to solid forms using various drying methods. Lyophilization is one such method and has the potential to stabilize mRNA, but there are few reports that describe the interactions of lyophilized mRNA with ex ...
DEF is a colorless liquid which is beneficial in the reduction of nitrogen oxide (NOx) emissions from diesel engines. The Selective Catalytic Reduction (SCR) system injects the DEF through a catalyst, converting the harmful nitrogen oxides into nitrogen, water, and carbon dioxide. Problems can occur ...
High-density polyethylene (HDPE) is a commonly recycled plastic, notably from plastic drinking bottles. Recycled applications of HDPE are many and various including new packaging and textile fibres. But it is especially valued in automotive applications including fuel tanks, wiring, cables, pipes an ...
Most cannabis extraction processes, independent of solvent or instrument choice, undergo a decarboxylation step whereby the carboxylic acid functional group is removed from the cannabinoids. The PerkinElmer Spectrum Two with the UATR accessory allows for the simple and rapid determination of cannabi ...
Thermogravimetric analysis (TGA) is a common technique that is used to study the weight loss during heating. It can tell you the percentage of weight loss quantitatively and accurately. But TGA alone will not tell you anything about the chemical components of the evolved off gas. The hyphenation bet ...
Infrared microscopy is a well-established analytical technique for the measurement and identification of small samples down to a few micrometers in size. It is used extensively in the polymer, pharmaceutical, chemical, food, and electronics industries, to name a few, often identifying small contamin ...
Cyanoacrylate adhesives also known as ‘superglues’ are single-component reactive adhesives. They cure with the small amount of moisture on the surface of the components and very quickly bond on a variety of substances. FTIR spectroscopy is used extensively within the adhesives industry for research, ...
Application Note, IR Spectroscopy, Polymer Recycling, Plastic Indentification Code, PIC, packaging materials, Spectrum Two, Diamond ATR, Mid-Infrared, Attenuated Total Reflectance, PET, HDPE, PVC, LDPE, PP, PS, Frontier, molecular spectroscopic
Paints and adhesives, although dissimilar materials with different purposes, have a commonality that they are typically liquid phase starting materials that end up as solid materials after a drying or curing period. Attenuated Total Reflectance (ATR) FTIR sampling methods are used extensively within ...
Pharmaceutical manufacturing Quality Assurance and Quality Control teams face many challenges including GMP compliance and data integrity, qualification of instrument performance, use of high quality consumables, data management, use of Informatics and Quality by Design principles. To help navigate ...
The application note discusses the Automated Fatty Acid Methyl Ester (FAME) Biodiesel Analysis using the PerkinElmer OilExpress 4 Platform. This advanced system automates the process of FAME biodiesel quantification in diesel blends, a critical requireme
As the importance of sustainable energy production increases, so too does the global commitment to using fuels from renewable biological sources. Biodiesel is one such renewable fuel. Consisting of fatty acids of methyl esters (FAME), it is produced from plant crops by transesterification – a reacti ...
The International North West 200 motorcycle road race is Ireland’s largest outdoor sporting event where skill and performance are pushed to the limits. To keep the focus on the riders and the bikes, the North West 200 requires each team to use a race-supplied control fuel. Determination of each team ...
This article describes methods for identifying and quantifying microplastics within organic-rich wastewater samples.
This article explains microscopic particle pollution in water with the effect also on food chain and decribes IR spectrometry analysis technique used to determine and quantify all kinds of plastic in the water.
Choose the PerkinElmer Frontier™ range of near-, mid- and far-IR Fourier Transform spectrometers for superior spectroscopic performance in demanding applications. Powerful and adaptable, the Frontier meets all your current analysis needs and can be expanded as your research goals evolve. And with au ...
Frontier™ is PerkinElmer’s most powerful, adaptable IR solution yet, specially developed to offer superior performance in demanding applications.
Innovation is the lifeblood of industrial polymer development – the push to improve materials or develop new ones infuses new life into the industry from R&D through to QA/QC. Manufacturers are continually challenged to ensure effective quality control and streamline processes while meeting stringen ...
This brochure describes easy to use, powerful, compact and robust – Spectrum Two™ IR spectrometer suited to a wide range of applications.
This brochure describes the Spotlight 150i and Spotligh 200i FT-IR Microscope System technology.
Download this interactive brochure to see all our biofuel lab solutions and supporting services. Maximize your laboratory's prospects in biofuels production and testing with PerkinElmer’s analytical solutions that can help you achieve high product qualit
CASE chemicals, also known as CASE materials are important to all facets of global industrial and consumer product manufacturing. The CASE chemicals category are made up of coatings, adhesives, sealants, and elastomers, all of which provide performance,
For higher educational institutions to continue to attract the highest caliber of students it is critical to have up-to-date technologies accessible in teaching laboratories. Historically, operational budgets have been limited and with intermittent use, universities could not justify the purchase. H ...
FAR, Field Application Report, Recycled Polyethylene Resin, Polypropylene Contamination, High-density polyethylene, HDPE, PP, PE, Fourier Transform Infrared Spectroscopy, FT-IR, Spectrum Two, ATR, Spectrum Quant
Your in-service lubricant testing lab demands high productivity and reliable results. Does your lab measure up to today’s standards with: Effortless high-throughput oil analysis Reliability and cost efficiency operations for highly automated, rapid, reliable oil condition monitoring results Recogniz ...
Regulatory demands are rising not only for pharmaceutical but also for environmental, cosmetics and personal care, nutraceutical, food and chemical industries compelling them to dedicate significant time to ensure their instruments meet compliance standa
This guide offers an overview of analyses required throughout the battery value chain - learn about innovative analytical solutions for testing every part of the battery, including the anode, cathode, binder, separator, and electrolyte. See the value in data generated from a variety of applications ...
PerkinElmer’s hyphenated solutions couple two or more instruments to greatly increase the power of analyses and save precious time by acquiring more information from a single run. The TGA 8000™ and STA systems coupled with FT-IR, MS, and/or GC/MS instruments represent the industry’s most complete an ...
Guide describing all UV/Vis spectroscopy, FT-IR spectroscopy, thermal analysis, hyphenation technique solutions for material characterization.
Coatings formulation and production can be as complicated as the product applications they are used for.
This poster lays out our whole material characterization range for the analysis of polymers and plastics. Find ideal techniques and instruments at each stage in the polymer manufacturing process: Resin Development - Resin Manufacture - Compound Development - Compound Manufacture - Product Forming - ...
Download this poster for an all-in-one view of how PerkinElmer instrumentation can answer the analytical needs of the solar market. From R&D of nanomaterials and advanced materials to solar cell component testing including aging and defect analysis - our UV/Vis, DSC, TGA, FT-IR and ICP systems help ...
This poster describes analytical application example of FT-IR microspectroscopy for microplastic analysis which are used as exfoliating microbeads in cosmetics and personal care products
This poster describes the detection and identification of plastics in the micron range in the context of oceans, surface waters, and other environmental compartments with the technique of FTIR combined with the features of microscopy and imaging.
Product Certificate for the Spectrum Two
The Atmospheric Vapor Compensation (AVC) function on the Spectrum™ Two and Frontier Series addresses the difficult task of reducing the effects of unwanted atmospheric absorptions in sample spectra.
Zinc selenide is a very useful material for infrared sampling optics, since it is transparent over most of the mid-infrared range, fairly hard and durable and resistant to water and most chemicals. Consequently it is widely used for attenuated total reflectance (ATR) and liquid transmission cells. ...
With our extended portfolio of cannabis testing products featuring best-in-class sample homogenization platforms, ICP-MS, LC/MS-MS, Headspace-GCMS, UHPLC and FTIR instruments and consumables, we help drive analytical best practices and operating procedur
Final product quality depends upon the correct type and quality of the raw materials used. A range of instrumentation can be used for raw materials ID, the most prominent being FTIR, typically in the mid- or near-IR spectral regions.
Recent supply chain issues have necessitated raw materials supplier changes, additional layers of materials testing and formulation pivots in order to keep up CASE materials and CASE chemicals production levels
The FDA defines data integrity as “completeness, consistency, and accuracy of data. Complete, consistent, and accurate data should be attributable, legible, contemporaneously recorded, original or a true copy, and accurate (ALCOA)”. ALCOA itself has evolved to ALCOA Plus, which incorporates two of t ...