Easy to use, powerful, compact and robust – Spectrum Two is the FT-IR spectrometer of choice for everyone, everywhere. With fully integrated, robust universal sampling for trouble-free measurements and portability options, Spectrum Two is ideal for use in both laboratory and remote testing environments. Ideally suited to everyday analysis, you can confidently perform fast, accurate IR analysis and assure the quality of your materials across a wide range of applications. Choose the Spectrum Two + that combines a powerful industrial-grade touch screen with cloud connectivity to offer you maximum productivity.

Part Number
Model Name
L160000A
Spectrum Two FT-IR Spectrometer (LiTaO3 Detector)
more
L160000F
Spectrum Two FT-IR Spectrometer (DTGS Detector)
more
L1390021
Spectrum Two N FT-NIR Spectrometer (LiTaO3 Detector)
more
L1390023
Spectrum Two N FT-NIR Spectrometer (InGaAs Detector)
more
L160000T
Spectrum Two Pharmaceutical System
more
L160000W
Spectrum Two Nutraceutical & TCM System
more
L160000Q
Spectrum Two In-Service Lubricant Analysis System
more
L160000S
Spectrum Two Environmental Hydrocarbon Analysis System
more
L160000U
Spectrum Two Educational System
more
L160000R
Spectrum Two IR Biodiesel Analysis System
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

High Performance FT-NIR That Goes Where You Go

Spectrum Two N FT-NIR spectrometer distills 75 years of PerkinElmer spectroscopy into a compact, high-performance yet robust FT-NIR. Simple to use, dependable and adaptable with optimized “plug-and-play” sampling accessories and modules coupled with a comprehensive software platform, Spectrum Two N systems are suited to a wide range of applications. Whatever your specific NIR application needs, in or out of the lab, the Spectrum Two N delivers outstanding performance and reliability to provide high-performance, dependable NIR measurement solutions.

Spectrum Two N FT-NIR spectrometers feature:

  • Standard, high-performance, room-temperature LiTaO3 (lithium tantalate) NIR detector
  • Optional, high-sensitivity, temperature stabilized InGaAs detector for use in quantitative, low light applications
  • Standard Atmospheric Vapor Compensation (AVC), Absolute Virtual Instrument (AVI), and Automatic Performance Verification (APV) for accurate and reproducible results anywhere
  • Optional Spectrum Two N Portability Pack enabling wireless connectivity, battery powered operation, and convenient transport with the dedicated Spectrum Two N carry case

For Every Application

PerkinElmer recognizes that every application is different. The result is a complete solution to provide the fastest assurance of the quality of your materials, regardless of the application. Some of the industry applications that the Spectrum Two N is designed to accommodate include:

  • Pharmaceuticals and nutraceuticals
  • In-service lubricants and fuels
  • Environmental
  • Polymers
  • Academia

For these specific applications, we offer various “plug-and-play” sampling accessories and modules enhancing the versatility of the Spectrum Two N FT-NIR.

Specifications

21 CFR Part 11 Compatible Yes
Depth 30.0 cm
Detector Type LiTaO3
Height 21.0 cm
Model Name Spectrum Two N FT-NIR Spectrometer (LiTaO3 Detector)
Operating Range 5 - 45 °C
Portable Yes
Product Brand Name Spectrum Two
Product Group Instrument
Warranty 1 year
Weight 13.0 kg
Width 45.0 cm

Configurations

Detector Software Part Number
LiTaO­3 Spectrum 10 L1390021
LiTaO­3 Spectrum 10 ES L1390022
InGaAs Spectrum 10 L1390023
InGaAs Spectrum 10 ES L1390024

 

 

Resources, Events & More
  • All

Application Note

A Comparison of Two FT-NIR Sampling Techniques for SIMCA Classification of Spectroscopically Similar Pharmaceutical Raw Materials

NIR Spectroscopy is a useful technique throughout various stages of the manufacturing process but is particularly useful for raw materials identification and verification. If the materials to be identified are spectroscopically dissimilar, it is often only necessary to use a simple distance measure ...

PDF 1 MB
Detecting Quinoa Flour Using FT-NIR

Quinoa flour is a high-value product and, therefore, susceptible to adulteration with lower-value flours. Fourier Transform Near-Infrared Spectroscopy (FT-NIR) provides a quick and easy method to determine the identity and concentration of any adulterants present in quinoa flour.

PDF 1 MB
Detection of Avocado Oil Adulteration

Avocado oil, a high-value product, may be adulterated with lower-value oils in order to increase profit margins. These adulterant oils may include nut-containing oils which may induce a dangerous allergic reaction for consumers with nut allergies. This works shows how near-infrared spectroscopy with ...

PDF 1 MB
Determination of THC and CBD in Cannabis Flower

This work shows an on-site, rapid and low-cost technique for the accurate measurement of flower potency. FT-NIR spectroscopy provides rich information regarding the chemical composition of cannabis flower. When combined with chemometrics, the FT-NIR offers unparalleled speed and simplicity that cann ...

PDF 1 MB
Discrimination of Herbal Lifestyle Products Using AssureID SIMCA and COMPARE Algorithms

Herbal lifestyle products are widely used as alternatives to medicines around the world, with as many as 80% of people using them as a primary source of healthcare in developing countries. These treatments are commonly regarded by scientific papers, and on some occasions the media, as being inferior ...

PDF 1 MB
Verification of Pharmaceutical Raw Materials using the Spectrum Two N FT-NIR Spectrometer

Near-infrared (NIR) spectroscopy is an important technique for materials checking at various stages of the manufacturing process, but is particularly useful at the raw materials inspection stage. Raw materials come in a variety of physical forms including liquids, gels, and solids, requiring a versa ...

PDF 2 MB

Brochure

Cannabis Testing Solutions Brochure

Whether your lab is well established or just starting up, having a single-source partner who can offer turnkey solutions that meet the current regulations is essential to a successful business. For years, we’ve worked with government and contract cannabis laboratories to develop industry-leading met ...

PDF 9 MB
Advanced Solutions for Biofuels Development and Testing

Download this interactive brochure to see all our biofuel lab solutions and supporting services. Maximize your laboratory's prospects in biofuels production and testing with PerkinElmer’s analytical solutions that can help you achieve high product qualit

Brochure

Flyer

Simplified In-Service Lubricant Analysis for OilExpress 4 Ensemble Flyer

Your in-service lubricant testing lab demands high productivity and reliable results. Does your lab measure up to today’s standards with: Effortless high-throughput oil analysis Reliability and cost efficiency operations for highly automated, rapid, reliable oil condition monitoring results Recogniz ...

PDF 955 KB
Universal Performance Verification

Regulatory demands are rising not only for pharmaceutical but also for environmental, cosmetics and personal care, nutraceutical, food and chemical industries compelling them to dedicate significant time to ensure their instruments meet compliance standa

Flyer

Regulatory Compliance Certification

Product Certificate - Spectrum Two N

Product Certificate for the Spectrum Two N

PDF 98 KB

Video

Customer Spotlight: Pride Analytics

With our extended portfolio of cannabis testing products featuring best-in-class sample homogenization platforms, ICP-MS, LC/MS-MS, Headspace-GCMS, UHPLC and FTIR instruments and consumables, we help drive analytical best practices and operating procedur

Video

White Paper

Data Integrity – Spectrum 10 Enhanced Security (ES) Software for Infrared Spectroscopy

The FDA defines data integrity as “completeness, consistency, and accuracy of data. Complete, consistent, and accurate data should be attributable, legible, contemporaneously recorded, original or a true copy, and accurate (ALCOA)”. ALCOA itself has evolved to ALCOA Plus, which incorporates two of t ...

PDF 3 MB
Selection Criteria for Analytical Technologies that Meet Polymer Manufacture and Recycling Testing Needs

This white paper discusses what testing is required at each step in the polymer production lifecycle from R&D to manufacture to recycling. It explores the analytical technologies that will meet those testing needs, and important considerations to help you select the instrumentation that will provide ...

PDF 1 MB