NexION 2000S ICP Mass Spectrometer | PerkinElmer
PerkinElmer
check quantity

NexION 2000S ICP Mass Spectrometer

PerkinElmer’s NexION® 2000 is the most versatile ICP-MS on the market, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatility of an instrument that makes it easy to handle any sample matrix, any interference, and any particle size.

PerkinElmer received on April 11, 2018 the Application Award from LaborPraxis in the category Bio and Pharma Analysis for the NexION 2000 ICP-MS. We were awarded this prize during analytica 2018 in Munich, Germany, in acknowledgment of a new technique enabling users to quantify the amount of metal in an individual cell for the first time.

Part Number
Model Name
N8150044
NexION 2000B
more
N8150045
NexION 2000C
more
N8150046
NexION 2000P
more
N8150047
NexION 2000S
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Ideal for laboratories testing semiconductors and fine chemicals, the NexION 2000S ICP-MS features:

  • A dedicated SMARTintro High Purity sample-introduction module minimizes contamination and delivers low background equivalent concentrations (BECs))
  • Built-in cold plasma capabilities which, combined with Reaction mode, deliver PPQ detection limits
  • Three quadrupoles, three gas channels, and three modes of operation combine to offer better interference removal, delivering better detection limits/improved data accuracy
  • The industry’s fastest data acquisition speed on the market (100,000 points/sec) to handle any particle size
  • A new solid-state RF generator with revolutionary LumiCoil technology – first ICP-MS RF coil that requires no maintenance or cooling
  • Triple Cone Interface with Quadrupole Ion Deflector, delivering no maintenance beyond the cones
  • Small footprint to minimize bench space
  • Syngistix software provides an intuitive interface that mirrors your workflow, with left-to-right, icon-based navigation that guides you through your analysis. Plus, it’s a cross-platform solution, easing the transition from technique to technique

The NexION 2000 ICP-MS – Triple Quad Power Meets Single Quad Versatility.

Specifications

21 CFR Part 11 Compatible Yes
Depth 69.0 cm
Height 75.0 cm
Model Name NexION 2000S
Portable No
Product Brand Name NexION
Warranty 1 Year
Weight 150.0 kg
Width 81.0 cm
Resources, Events & More
  • All

Application Brief

Determination of Organotin in Tap Water by HPLC-ICP-MS in Accordance with Chinese Method HJ 1074-2019

Organotin compounds are widely used across industry and agriculture, resulting in widespread pollution of various environmental media, including potable water. Among these compounds are tributyltin (TBT), triphenyltin (TPT), dibutyltin (DBT), and diphenyltin (DPT), in the following order of persiste ...

PDF 506 KB
PM10 and PM2.5 Air Pollution Monitoring and Source Apportionment in Asia Using the NexION ICP-MS

Concern about air pollution has been growing rapidly, with most of the focus on gaseous pollutants. Airborne particulates, especially small ones, are rapidly gaining attention due to their impact on human health, as smaller particles can be carried over long distances by wind and penetrate deep into ...

PDF 1 MB

Application Note

A Single Cell-ICP-MS Method to Study the Treatment Efficiency of Algaecide for Toxic Algal Bloom Control

Toxic cyanobacterial blooms were reported worldwide in various aquatic systems, including freshwater rivers, lakes, reservoirs, and eutrophied coastal marine habitats. Cyanobacterial blooms might be caused by a combination of multiple factors, including eutrophication, solar radiation, temperature, ...

PDF 2 MB
Accurate Sizing and Counting of 10 nm Gold Nanoparticles with the NexION ICP-MS

In this work, we demonstrate that PerkinElmer's NexION® 2000 ICP-MS, with its unique RF generator and ion optics, coupled with the Syngistix™ Nano Application Software Module, can be used to accurately measure and characterize NP sizes of 10 nm and smaller, both alone and in a mixture of NPs of vari ...

PDF 2 MB
Analysis of Cerium Dioxide Nanoparticles in Soil Using Single Particle ICP-MS

This work demonstrates a robust method using SP-ICP-MS technology to detect CeO2 NPs which were extracted from soil samples with tetrasodium pyrophosphate (TSPP). Over the past few decades, engineered nanoparticles (ENPs) have been increasingly used in many commercial products. As a result, more and ...

PDF 1 MB
Analysis of Drinking and Natural Waters with the NexION 2000 ICP-MS

This work has demonstrated the ability of the NexION 2000 ICP-MS to analyze both natural and drinking water samples in Standard (i.e. non-cell) mode, in accordance with U.S. EPA Method 200.8. Accuracy has been demonstrated through the analysis of several reference materials and spike recoveries, wit ...

PDF 1 MB
Analysis of Iron Nanoparticles in Semiconductor Organic Solvents Using Single Particle ICP-MS in Reaction Mode

Metallic contamination in semiconductor products adversely affects device performance. Transition metals are among the most commonly occurring forms of metal contamination – they tend to diffuse through the semiconductor material and aggregate on the surface in various oxide forms, and iron (Fe) is, ...

PDF 1 MB
Analysis of Rare Earth Elements by Laser Ablation-ICP-MS with the NexION 2000 ICP-MS

With the increasing development of high-tech applications, rare earth elements (REEs) are considered key elements for modern and future industries. Globally, there is growing pressure for analytical solutions that can accurately characterize and quantify REE content in a high-throughput manner to me ...

PDF 1 MB
Analysis of Soils and Waters Following U.S. EPA Method 6020B using the NexION 2000 ICP-MS

Through the years, both industry and analytical instrumentation have advanced. With the development of new chemicals and processes, new pollutants may enter the environment. However, the capabilities of analytical instruments have also increased, allowing the measurement of ever lower levels of envi ...

PDF 2 MB
Boron Isotope Ratio Analysis Using the NexION ICP-MS

Boron (B) is studied for its isotope ratio composition in a range of paleoproxy, geochemical, nuclear, medical, and archeological applications. ICP-MS is recognized as a powerful technique for boron isotope analysis. Quadrupole ICP-MS is versatile and not exclusively dedicated to isotope ratio measu ...

PDF 3 MB
Characterization of Nanoparticle Element Oxide Slurries Used in Chemical-Mechanical Planarization by Single Particle ICP-MS

In semiconductor device fabrication, in an effort to reduce the size of electronic devices and improve the yield of the manufacturing process, chemical-mechanical planarization (CMP) slurries consisting of nanoparticles are now in use. CMP is a process of smoothing surfaces with the combination of c ...

PDF 1 MB
Characterization of TiO2 Nanoparticle Release from Fabrics By Single Particle ICP-MS

In the textile industry, the use of titanium dioxide (TiO2) nanoparticles (NPs) is increasing due to their ability to provide UV protection, increase the hydrophilic nature of fabrics, provide antibacterial characteristics, and reduce odors. This work demonstrates the ability of PerkinElmer's NexION ...

PDF 516 KB
Compendium - Reliable Methods for Nutritional & Toxic Analysis of Breakfast Foods

Breakfast is an important meal in providing essential nutrients to keep your energy levels up throughout the day. How do we ensure the food and beverages we consume are healthy, nutritious and safe? Following is a collection of application notes highlighting solutions that will help you identify mic ...

PDF 15 MB
Determination of Impurities in Lithium Materials with the NexION 2000 ICP-MS

With growing concern about the state of the environment, more and more devices are being powered by lithium batteries due to their higher capacities, longer lives, and ability to be recycled, in comparison to conventional batteries. As with all consumer goods, safety and performance are critical and ...

PDF 1 MB
Iron Nanoparticles by SP-ICP-MS: Overcoming Spectral Interferences Using Universal Cell Technology

With the increasing interest in nanoparticles (NPs), various ways of detecting and measuring them are being used. One of the most promising techniques for analyzing metallic NPs is single particle ICP-MS (SP-ICP-MS). This work demonstrates the ability of the NexION® SP-ICP-MS with Universal Cell Tec ...

PDF 1 MB
Monitoring the Fate of Silver Nanoparticles in Seawater Using Single Particle ICP-MS

Single Particle (SP) ICP-MS is an analytical technique that has demonstrated tremendous potential for the measurement and characterization of metal-containing nanoparticles (NPs) in a wide range of sample types, including environmental. One of the most challenging matrices is seawater due to its hig ...

PDF 1 MB
New Research Evaluating Cisplatin Uptake in Ovarian Cancer Cells by Single Cell ICP-MS

Cisplatin, carboplatin, and oxaliplatin are the most widely used of platinum-based cancer chemotherapy drugs in the Western world. Cisplatin's effectiveness is due to its ability to bind to the DNA, resulting in DNA-platinum (Pt) adducts, which bend the DNA. The cells must then repair the DNA damage ...

PDF 2 MB
NexION 2000: A Perfect Tool for the Determination of Trace Elements in Blood and Serum

This work demonstrates the ability of PerkinElmer's NexION 2000 ICP-MS to perform accurate, stable analyses of blood and serum samples, leveraging the benefits of the Universal Cell and the ability to use three cell gases in a single method.

PDF 931 KB
Quantification of Nanoparticle Uptake into Cancer Cells using Single Cell ICP-MS

Nanoparticles (NPs) have been of significant interest over the last two decades as they offer attractive benefits for drug delivery to overcome limitations in conventional chemotherapy. Nanoparticles can be engineered to carry both drugs and imaging probes to simultaneously detect and treat cancer. ...

PDF 906 KB
SP-ICP-MS Analysis of Size and Number Concentration in Mixtures of Monometallic and Bimetallic (Core-shell) Nanoparticles

Separating and measuring the physical and chemical properties of monometallic and bimetallic engineered nanoparticles (NPs) is challenging, especially when mixtures of NPs consist of particles of similar size, composition, and especially when present at low concentrations. Fully characterizing suspe ...

PDF 1 MB
Testing and Validation of Various Antacids for Elemental Impurities using the NexION 2000 ICP-MS

The United States Pharmacopeia (USP) has announced that its new standards for elemental impurities in drug products has been implemented since January 1, 2018. General Chapters <232> and <2232> specify the list of elements and their permissible daily exposure (PDE) limits based on the route of admin ...

PDF 576 KB
Transport of Nanoparticles from Coated Surfaces through Physical Contact

This work investigated the transfer of Ag and CuO nanoparticles from consumer products via simulated dermal contact by using textile wipes as a surrogate using PerkinElmer’s NexION® ICP-MS single particle analyzer with the unique Syngistix™ Nano Application software module for data collection and an ...

PDF 1 MB

Brochure

Cannabis Testing Solutions Brochure

Whether your lab is well established or just starting up, having a single-source partner who can offer turnkey solutions that meet the current regulations is essential to a successful business. For years, we’ve worked with government and contract cannabis laboratories to develop industry-leading met ...

PDF 9 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, and ...

PDF 3 MB
Grain Testing Solutions Brochure

The grain industry is very complex. It’s global, diverse, and can also present analytical challenges. Today’s grain users demand more when it comes to quality, safety, and uniformity. In addition, they seek diverse products with unique characteristics. PerkinElmer is equipped to help the grain indus ...

PDF 6 MB
Meat and Seafood Testing Solutions

Food testing labs like yours are constantly challenged with accurately analyzing samples quickly and efficiently - all while striving to reduce costs due to market forces. Your commitment to ensuring meat and seafood are safe for consumption, as demand increases, is an uphill battle. Our commitment ...

PDF 6 MB
NexION 2000 ICP Mass Spectrometer

Unrivaled ppq detection limits. Unparalleled usability. Finally analysts can have the best of both worlds with the NexION® 2000 ICP-MS, featuring an array of unique technologies that combine to deliver the highest performance no matter what your analytical challenge. Discover the effortless versatil ...

PDF 1 MB
Refinery and Natural Gas Analysis Brochure

Oil refineries and natural gas producers around the world require their lab operations to perform large numbers of analyses before their products are used in industries and by consumers. Detection of even the slightest impurities, accurate process control and hydrocarbon distribution analysis is cri ...

PDF 5 MB
USP <232>/<233> & ICH Q3D Capabilities Brochure

The International Conference on Harmonization Guideline for Elemental Impurities Q3D (ICH Q3D) has established maximum permitted daily exposure limits for elemental impurities in pharmaceutical products. In combination with the U.S. Pharmacopeia’s (USP) Chapters <232> and <233> on elemental impuriti ...

PDF 3 MB

Case Study

NutriControl and PerkinElmer Collaborate to Serve-up Agricultural and Nutritional Analyses

The science and art of creating and maintaining thriving agricultural ecosystems requires cultivating healthy soil, crops and livestock. The safety and efficacy of agricultural chemicals and their uptake into our food supply requires robust, reliable and effective analytical testing on agrochemicals ...

PDF 393 KB

Catalog

Atomic Spectroscopy Consumables Catalog

Download your complete PDF catalog containing all the consumables needed to keep your Atomic Absorption, ICP-OES, and ICP-MS instruments up and running.

PDF 8 MB

Flyer

S20 Series Autosamplers

The S20 series is the next generation of high-performance, robust, and agile autosamplers designed specifically for PerkinElmer’s spectroscopy platforms - atomic and molecular. The series is comprised of two autosamplers: the S23 with three racks and the S25 with five racks. They are designed to mee ...

PDF 1 MB
Supporting Sustainability with the NexION ICP-MS Series

Today’s sustainable solutions are opening exciting new ways for businesses to fuel economic growth, while minimizing adverse impact on people and the planet. Laboratories are also working sustainability into their business plans to reduce downtime, waste, and costs – and in many cases, improve their ...

PDF 587 KB

Guide

NexION 1000/2000 ICP-MS Preparing Your Laboratory

PerkinElmer ICP-MS instruments are complete systems with the exception of the following items which must be provided by the customer: electrical power, exhaust vents, argon gas supplies with approved regulator, cell gas supply with approved regulators

PDF 1 MB
NexION ICP-MS Series Consumables & Supplies Guide

Whether looking for sample introduction components or standards, we have the consumables you need to keep your NexION up and running smoothly and efficiently.

PDF 2 MB

Poster

Advanced Solutions for Solar Cells Poster

Download this poster for an all-in-one view of how PerkinElmer instrumentation can answer the analytical needs of the solar market. From R&D of nanomaterials and advanced materials to solar cell component testing including aging and defect analysis - our UV/Vis, DSC, TGA, FT-IR and ICP systems help ...

PDF 1 MB

Product Note

High Throughput System for ICP-MS and ICP-OES Product Note

Our High Throughput System (HTS) is a uniquely designed modular sample introduction that integrates with the NexION® series of ICP-MS and the Avio® series of ICP-OES to dramatically reduce sample-to-sample time, thereby improving sample throughput while maintaining operation simplicity. The HTS maxi ...

PDF 1 MB
Syngistix Atomic Spectroscopy Enhanced Security Software Product Note

PerkinElmer’s Syngistix Enhanced Security software for AA, ICP and ICP-MS meets the special needs of highly regulated labs such as those that must comply with the U.S. FDA’s 21 CFR Part 11 regulations.

PDF 1 MB

Regulatory Compliance Certification

Product Certificate - NexION 1000/2000

Product Certificate for the NexION 1000/2000

PDF 98 KB

Technical Note

Advantages of a Novel Plasma Generator for the NexION 1000/2200/5000 ICP-MS Systems

Unlike other ICP-MS systems on the market that utilize conventional 40-MHz or 27-MHz commercially available generators which are typically customized and modified to work with ICP-MS instruments, the NexION® 1000/2200/5000 ICP-MS systems feature a 34-MHz frequency free-running RF generator, which wa ...

PDF 1 MB
All Matrix Solution System for NexION ICP-MS Platforms

PerkinElmer’s All Matrix Solution (AMS) system provides a number of benefits to simplify analysis of high-matrix samples with the NexION family of ICP-MS instruments. It allows online gas dilution, improving efficiency and preventing contamination, delivering up to 200x dilution and the ability to s ...

PDF 1 MB
TotalQuant Analysis in NexION ICP Mass Spectrometers

TotalQuant, a software feature unique to PerkinElmer's NexION® ICP-MS systems, intelligently interprets the complete mass spectrum, providing semi-quantitative to quantitative results for all elements. TotalQuant and survey scan can provide supplementary and confirmatory information about unknown sa ...

PDF 1 MB
Unlocking Carbon-13 with Single Particle ICP-MS: Feasibility Study for Microplastic Detection

Carbon is difficult to measure with ICP-MS because of its high ionization potential and its presence in both the argon used to generate the plasma (primarily in the form of CO2, as an impurity) and in reagents, including acids and water. As a result, extremely high backgrounds exist at both of the n ...

PDF 1 MB

Training

Webinars

White Paper

The Determination of Metals in Non-Medical Face Masks

With the onset of the COVID-19 pandemic, the use of face masks by the general public has become a critical personal protective measure to minimize person-to-person transmission. While health care workers use medical or surgical masks, the general population uses non-medical, otherwise known as hygie ...

PDF 683 KB