Prepacked tubes are a time saving and cost effective alternative to packing your own tubes. All combustion tubes are pressure-tested to eliminate any tubes which might contain weak spots. In addition, stringent specifications are used to insure that the combustion tubes fit in an airtight connection when placed in the analyzer.
Sort by
1-16 of 16 Products & Services
The Prepacked CHNS/Oxygen Reduction Furnace Tube is found in the Oxidation Analysis Kit and the CHNS Analysis Kit. With this part number, you can order a replacement or spare. Qty. 1
The CHN Prepacked Oxidation Pyrolysis Tube is found in the Oxidation Analysis Kit. These tubes have an estimated life of 1000 runs. These tubes are packed with Platinized Carbon and Cuprin. With this part number, you can replenish your supply. Qty. 1
The CHNS Prepacked Silica Reduction Tube is found in the CHN Analysis kit. These tubes have an estimated life of 2000 runs. These tubes are packed with the reagents Copper + and Cuprox. With this part number, you can replenish your supply. Qty. 1
The CHNS Prepacked Oxidation/Reduction Tube is found in the CHNS Analysis Kit. These tubes contain the reagents EA 6000 and Cuprin. They have an estimated life of 70 runs. With this part number, you can replenish your supply. Qty. 1
These quartz reduction tubes are composed of pure fused quartz which is 99% SiO2. Fused quartz has been chosen because of its very high purity and low thermal expansion rate. All combustion tubes are pressure tested to eliminate any tubes which might contain weak spots. In addition, strict specifications are used to ensure that the combustion tubes fit in an airtight connection when placed in the analyzer.
This quartz oxygen pyrolysis tube is used with the PerkinElmer 2400 Series II Analyzer.
These quartz reduction tubes are composed of pure fused quartz which is 99% SiO2. Fused quartz has been chosen because of its very high purity and low thermal expansion rate. All combustion tubes are pressure tested to eliminate any tubes which might contain weak spots. In addition, strict specifications are used to ensure that the combustion tubes fit in an airtight connection when placed in the analyzer. This scrubber tube is included in the PerkinElmer 2400 Series II Oxygen Analysis Kit (N2410513).
These quartz reduction tubes are composed of pure fused quartz which is 99% SiO2. Fused quartz has been chosen because of its very high purity and low thermal expansion rate. All combustion tubes are pressure tested to eliminate any tubes which might contain weak spots. In addition, strict specifications are used to ensure that the combustion tubes fit in an airtight connection when placed in the analyzer. This tube is included in the PerkinElmer 2400 Series II Sulfur Analysis Kit (N2410512).