Simultaneous Thermal Analyzer (STA) 8000 | PerkinElmer
PerkinElmer
check quantity

Simultaneous Thermal Analyzer (STA) 8000

The STA 8000 simultaneous thermal analyzer offers performance, reliability and productivity you can depend on.

We stand firmly behind our products and now offer a 5 YEAR PARTS ONLY FURNACE WARRANTY* with new instruments.

Part Number N5370027
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

*Not available in all regions. Terms and Conditions apply. Warranty is void if the product is misused.

Overview

  • Simultaneous analysis of TG with DTA mode (?T) and DSC (mW) mode for fast enhanced result interpretation
  • Wide temperature range allow measurements from below room temperature to 1600 °C. Superior accuracy and sensitivity in a small package with an attractive price
  • Superior weight, heat flow and temperature accuracy in a small package with an attractive price
  • Top loading balance for ease of sample loading
  • Balance below furnace for optimum isolation from contamination
  • Vertical displacement balance sensor (not rotational) provides weight insensitivity to sample position, e.g., no spurious weight change from melting

Specifications

21 CFR Part 11 Compatible Yes
Maximum Temperature 1600 °C
Minimum Temperature 15 °C
Model Name STA 8000
Portable No
Technology Type Thermal Analysis
Resources, Events & More
  • All

Application Note

Application of TMA and STA to Optimize the Sintering Process of Solid-state Electrolyte Used in All-solid Battery

All-solid-state lithium-ion batteries have received extensive attention as the core technology for the next generation of power batteries, with solid-state electrolytes as the key component. Lithium aluminum titanium phosphate (LATP) with a NASICON structure exhibits outstanding properties in terms ...

PDF 1 MB
Polymer Applications Compendium

Today’s plastics are some of the most used materials on a global volume basis. Broadly integrated into today’s industrial and commercial lifestyles, they make a major, irreplaceable contribution to virtually every product category. In this compendium you will find a wide range of applications for po ...

PDF 57 MB
Proximate Analysis of Coal and Coke using the STA 8000 Simultaneous Thermal Analyzer

The purpose of this study is to demonstrate the proximate analysis of two standard samples using the STA and show that the performance is easily able to allow this moderate cost, small profile and sturdy instrument to be used for this type of routine analysis.

PDF 1 MB
Use of the STA 8000 Simultaneous Thermal Analyzer for Melt Analysis of Alloys

The requirements for melt analysis of alloys include accurate temperature and melt energy measurement and the ability to exclude oxygen – or if necessary, nitrogen – during the analysis. With the ability to provide microgram-level weight change detectability of sample loss or oxidative gain, Simulta ...

PDF 950 KB

Brochure

Simultaneous Thermal Analyzers

The PerkinElmer range of Simultaneous Thermal Analyzers (STA), offers you real-time measurement and analysis of sample weight change and heat flow. With innovative sensor technology and compact furnace design, our STA instruments are ideally suited for both research and routine applications.

PDF 398 KB

Ebook

Palm Oil Analysis. Complete lab solutions from upstream to downstream

Quality control-monitoring and testing are important in ensuring the quality of palm oil. The quality control parameters are used to judge the quality of palm oil products and it can be monitored and tested to ensure that the palm oil is not deliberately or accidentally adulterated.

PDF 11 MB

Flyer

Laboratory Solutions for Lubricant Analysis

Increasing demands for efficiency, productivity, data quality, and profitability pose ongoing challenges for lubricant testing laboratories, like yours, performing new lubricant or in-service oil analyses. Whether you need to achieve quick turnaround times, minimize downtime, or maximize lab efficie ...

PDF 542 KB
Qualitative Analysis of Evolved Gases in Switchgrass by TG-GC/MS

The hyphenation of TG-GC/MS is a powerful tool for quality control, safety, and product development. This Flyer discusses the utility of PerkinElmer TG-GC/MS with an example application – the identification of specific organic acids evolved during TGA analysis of switchgrass.

PDF 267 KB

Guide

Evolved Gas Analysis - Hyphenated Technology Guide

The needs for polymer, pharmaceutical, chemicals, food and beverage, and environmental analyses are constantly changing due to innovation demands and regulation changes. Evolved Gas Analysis (EGA) solutions combine multiple analytical technologies to empower speed and advanced information acquisitio ...

PDF 3 MB
Hyphenated Technology Compendium of 21 Application Notes

PerkinElmer’s hyphenated solutions couple two or more instruments to greatly increase the power of analyses and save precious time by acquiring more information from a single run. The TGA 8000™ and STA systems coupled with FT-IR, MS, and/or GC/MS instruments represent the industry’s most complete an ...

PDF 7 MB

Manual

PerkinElmer STA 8000 Installation and Hardware Guide

The STA 8000 Installation and Hardware Guide provides an overview of instructions for the safe and proper installation of STA 8000.

PDF 690 KB

Poster

Advanced Solutions for Polymers and Plastics

This poster lays out our whole material characterization range for the analysis of polymers and plastics. Find ideal techniques and instruments at each stage in the polymer manufacturing process: Resin Development - Resin Manufacture - Compound Development - Compound Manufacture - Product Forming - ...

PDF 2 MB

Regulatory Compliance Certification