Light Hydrocarbons/Fixed Gas Analyzers by TCD | PerkinElmer
PerkinElmer
check quantity

Light Hydrocarbons/Fixed Gas Analyzers by TCD

Our solutions are designed specifically to ensure your compliance with regulatory methods ASTM D1946 and E1746 for chlorine impurities analysis, while also optimizing productivity and ROI. Our series of analyzers utilize a combination of gas chromatography (GC) and a thermal conductivity detector (TCD), providing an efficient and robust solution for the analysis of gaseous samples. Alert - ASTM E1746, Model 4020: In response to the COVID-19 crisis, PerkinElmer addresses ASTM E1746 “Standard Test Method for Sampling and Analysis of Liquid Chlorine for Gaseous Impurities” in order to serve the needs of chemicals producers aiding in the current bleach and bleach-based wipe disinfectants shortage. Learn more about the Chlorine Analyzer here.

Part Number
Type
Detection Method
Detector Type
NARL8514
Model 4016
ASTM D1946
TCD
more
NARL8515
Model 4017
ASTM D1946
TCD/TCD
more
NARL8517
Model 4019
ASTM D1946
TCD/TCD/TCD
more
NARL8518
Model 4020
ASTM E1746
Two Single TCDs
more
NARL8552
Model 4016Ar
ASTM D1946
TCD
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

Utilizing a single thermal TCD and packed columns, Model 4016 can be paired with a number of optional channels including an FID (Flame Ionization Detector) for better hydrocarbon detection, a Methanizer/FID and purged-valve housings for trace CO and CO2 analysis, an FPD (Flame Photometric detector) or a sulfur chemiluminescence detector for sub-ppm levels of hydrogen sulfide and other light sulfur compounds. Meeting the needs of operations required to analyze samples for ASTM D1946, PerkinElmer’s Model 4016 guarantees detection limits of 0.02% for H2S, and 0.01% for Ar-O2 composite, N2, CH4, CO, CO2, ethylene, ethane and acetylene.

Specifications

Detection Method ASTM D1946
Detector Type TCD
Type Model 4016
Resources, Events & More
  • All

Application Brief

Quantification of Light Gases Contaminants in Chlorine by Chlorine Analyzer Application Brief

From keeping our drinking water safe to disinfecting our public transportation systems and hospitals, chlorine chemistry plays a critical role in the manufacturing of thousands of products we depend upon to remain healthy. Whether it’s used in the manufacturing processes or in a final product, chlor ...

PDF 1 MB

Flyer

The PerkinElmer Chlorine Analyzer Flyer

How does the PerkinElmer Chlorine Analyzer keep Chlorine manufacturers producing to meet the global need? The PerkinElmer Chlorine Analyzer is a factory preconfigured and validated, turnkey gas chromatography (GC) solution, to obtain quick and reliable chlorine purity results, with a low cost of own ...

PDF 163 KB