PinAAcle 500 Flame Atomic Absorption Spectrometer | PerkinElmer
PerkinElmer
check quantity

PinAAcle 500 Flame Atomic Absorption Spectrometer

Our PinAAcle 500 is the world’s first completely corrosion-resistant flame atomic absorption (AA) spectrometer, designed to withstand the harshest environments and most corrosive samples. It offers superior durability, longer life, lower maintenance costs, and the fastest return on investment of any flame AA.

Part Number PinAAcle500
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

The PinAAcle 500 is a robust, fully-integrated, flame-only benchtop system, ideal for laboratories needing a reliable, easy-to-use, yet high-performance flame AA. It is equipped with an innovative touchscreen interface with the flexibility to operate via its easy-to-use Syngistix Touch software or the more comprehensive, optional Syngistix for AA Software.

The PinAAcle 500 is designed for:

  • Exceptional sensitivity and precision, allowing analysis of lower concentrations with the accuracy of higher-end AA systems
  • Fast, simple, reproducible operation through the intuitive, icon-based interface of Syngistix Touch or Syngistix for AA
  • Harsh environments and samples thanks to its corrosion-resistant sample introduction components
  • Minimum maintenance and maximum speed with a rugged design that virtually eliminates maintenance, reducing operating costs

The PinAAcle 500 is engineered to deliver an uncompromising level of performance at an unbeatable price, putting the industry’s most robust, reliable flame AA within reach of even the most budget-conscious laboratories. Discover an instrument engineered to outlast and outperform… and take your laboratory to a new PinAAcle of productivity and profitability. 

Specifications

21 CFR Part 11 Compatible Yes
Height 64.0 cm
Model Name PinAAcle 500
Portable No
Product Brand Name PinAAcle
Warranty 1 Year
Weight 57.0 kg
Width 67.0 cm
Resources, Events & More
  • All

Application Note

Accurate Determination of Lead in Dairy Products by Graphite Furnace Atomic Absorption

The performance of this method was validated by assessing the Standard Reference Materials (SRMs) from the US National Institute of Standards and Technology (NIST) and China National Institute of Metrology (NIM) as well as by comparing these results with those obtained using inductively coupled plas ...

PDF 724 KB
Analysis of Arsenic, Cadmium and Lead in Chinese Spice Mixtures using Graphite Furnace Atomic Absorption SPectrophotometry

This application note describes an accurate and reliable microwave-assisted sample pretreatment procedure for the determination of arsenic, cadmium and lead in spices using graphite furnace atomic absorption spectrophotometry (GFAAS).

PDF 1 MB
Analysis of Fish and Seafood with the AAnalyst 800 Atomic Absorption Spectrophotometer for Trace Metal Contamination in Accordance with AOAC Methods 999.10 and 999.11

Increased knowledge about the nutrient content of biological organisms is essential for a thorough understanding of ecological stoichiometry and nutrient transport in and among ecosystems.

PDF 334 KB
Analysis of Lead, Cadmium, and Arsenic in Spice Mixtures

With an inherent toxicity, a tendency to accumulate in the food chain and a particularly low removal rate through excretion, lead (Pb), cadmium (Cd) and arsenic (As) cause harm to humans even at low concentrations.

PDF 766 KB
Analysis of Micronutrients in Fruit Juice Using FAST Flame Sample Automation for Increased Sample Throughput

Consumers select fruit juice because it is a tasty, convenient beverage and generally understood to be a more nutritious alternative to carbonated beverages. For 100% juice products, the nutrition content of the original fruit itself is well known, which translates to the expected nutritional value ...

PDF 1 MB
Analysis of Micronutrients in Milk by Flame Atomic Absorption

Milk is an important source of nutrients, mainly for children. Because of its importance, milk is available in several different forms, most commonly as fresh, but it is also available in nonperishable forms (such as powdered and evaporated). Therefore, the requirement exists to analyze several form ...

PDF 1 MB
Analysis of Micronutrients in Soil by Using AA 800 Atomic Absorption Spectrophotometer

Soil is used in agriculture, where it serves as the primary nutrient base for the plants. Soil material is a critical component in the mining and construction industries. Soil serves as a foundation for most construction projects.

PDF 415 KB
Analysis of Organic Fertilizers for Nutrients with AAnalyst 800 Atomic Absorption Spectrophotometer

The fertilizer industry helps to ensure that farmers have the nutrients they need to grow enough crops to meet the world's requirements for food, feed, fiber and energy.

PDF 399 KB
Analysis of Pb, Cd and As in Tea Leaves Using Graphite Furnace Atomic Absorption Spectrophotometry

For many years, graphite furnace atomic absorption spectrophotometry (GFAAS) has been a reliable technique and the preferred method for this heavy metals analysis of tea leaves.

PDF 589 KB
Analysis of Vanadium, Nickel, Sodium, and Iron in Fuel Oils using Flame Atomic Absorption Spectrophotometry

Elemental analysis of fuel oil is an important step in quantifying its quality. Combustion of fuels containing metals can lead to the formation of low melting-point compounds that are corrosive to metal parts. The presence of certain metals, even at trace levels, can deactivate or foul catalysts use ...

PDF 1 MB
Determination of Arsenic in Baby Foods and Fruit Juices by GFAAS

Arsenic can find its way into food through a variety of paths. In the recent past, various organic arsenicals were used as herbicides and antimicrobial agents in growth fields as well as applied directly on fruits and fruit trees.

PDF 1 MB
Determination of As, Se and Hg in Waters by Hydride Generation/Cold Vapor Absorption Spectroscopy

Contamination of industrial and municipal water supplies with arsenic (As), selenium (Se), and mercury (Hg) can occur from natural deposits, industrial discharge, runoff from mining, landfill and agricultural operations.

PDF 1 MB
Determination of Toxic, Trace and Essential Elements in Food Matrices using THGA Coupled with Longitudinal Zeeman Background Correction

Ingestion of trace elements from food can be linked to nutrition, disease, and physiological development. Whether they are needed for proper nutritional value or contain toxic elements, the presence of major and minor elements in food needs to be verified to help determine health effects for the con ...

PDF 752 KB
Determination of Various Elements at Ultra-trace Levels in Ultrapure Acids and Photoresist Stripper Solutions by Graphite Furnace Atomic Absorption

To protect the integrity of semiconductor and electronics end-products, semiconductor researchers and developers (R&D) and manufacturing QA/QC functions face unique challenges to reduce contaminates, sometimes down to ultra-trace levels. Metal determination in the sub-ppb range are required for the ...

PDF 1 MB
Elemental Analysis of Beer by Flame Atomic Absorption with the PinAAcle 900

This work demonstrates the ability to measure several elements in beer with Flame atomic absorption using the PinAAcle 900. No significant differences were observed between beers in glass bottles or metal cans.

PDF 953 KB
Micronutrients in Fortified Breakfast Cereal by Flame AA Using Microwave Digestion and FAST Flame Automation

Fortified breakfast cereals are an important source of nutrition for children, and consumers have come to expect high quality from a variety of cereals and continue to select fortified products over non-fortified products in the marketplace. The efficient production of these nutritionally fortified ...

PDF 1 MB
Micronutrients in Fresh and Dried Fruits by Flame AA Using Microwave Digestion and FAST Flame Automation

With an increased focus on healthy living and the consumption of healthy foods, interest in the nutritional quality of the fruit we consume has become more important. When fresh fruit is not available, dried fruit is often substituted, and manufacturers and customers would like to know that the drie ...

PDF 1 MB
Quantification of Essential Metals in Spice Mixtures for Regulatory Compliance Using Flame Atomic Absorption Spectrophotometry

There is an increasing need to monitor the essential element levels in food samples at ever decreasing concentrations. For this purpose, very sensitive, yet rapid and inexpensive methods are necessary. The quantification of trace metals in food samples has routinely been carried out by ICP-OES, ICP- ...

PDF 993 KB
The Analysis of Baby Foods and Juices for Metals to Protect a Sensitive Population

Foods, infant formula, milk, and water provide significant exposure routes for metal contaminants. The effect of lead exposure at low levels has been well established and levels below toxic have been shown to contribute to behavioral and learning issues. In this work both the GFAA and ICP-MS methods ...

PDF 880 KB
The Analysis of Copper, Iron, and Manganese in Wine with FAST Flame Atomic Absorption

This work demonstrates the ability of the PinAAcle 900 flame AA spectrometer to measure Cu, Fe, and Mn in wines to comply with Chinese wine import regulations coupled with FAST Flame sample automation for increased throughput.

PDF 747 KB
The Analysis of Copper, Iron, and Manganese in Wine with the PinAAcle 500

With the popularity of wine consumption continuing to grow, regulations are being implemented as to the metal content allowed in wines. These analyses can be easily accomplished using flame atomic absorption (AA) spectrometry. This work demonstrates the accurate analysis of copper (Cu), iron (Fe), a ...

PDF 1 MB
The Analysis of Major Elements in Drinking Water Using FAST Flame Sample Automation for Increased Sample Throughput

This work demonstrates the analysis of mineral elements in a variety of drinking waters using the PinAAcle 900 AA spectrometer coupled with a FAST Flame accessory.

PDF 764 KB
The Analysis of Minerals in Drinking Water with the PinAAcle 500

This work demonstrates the ability of the PinAAcle 500 Flame AA spectrometer to accurately measure major components in drinking waters.

PDF 991 KB
The Analysis of Precious Metals in Mining with the PinAAcle 500

When mining for precious metals, ores are extracted from the ground and subjected to various sample preparation procedures in order to remove the metals of interest. A commonly used procedure to isolate metals from the ore is fire-assay, which leaves a matrix-free “button” of the metal. This work fo ...

PDF 1 MB
The Determination of Minerals and Metals in Multi-Mineral/Multi-Vitamin Tablets by Flame Atomic Absorption Spectroscopy

There are many mineral dietary supplements available in today's marketplace to ensure that mineral deficiencies do not occur in one's diet. The mineral content of these products must be verified for quality control purposes.

PDF 427 KB
Toxic Trace Metals in Edible Oils by Graphite Furnace Atomic Absorption Spectrophotometry

Graphite furnace atomic absorption spectrophotometry (GFAAS) has been widely applied to the determination of trace elements in food due to its selectivity, simplicity, high sensitivity, and its capability for accurate determinations in a wide variety of matrices. Edible oils are generally low in tra ...

PDF 379 KB
Trace Elemental Characterization of Edible Oils with Graphite Furnace Atomic Absorption Spectrophotometer

The determination of the inorganic profile of oils is important because of the metabolic role of some elements in the human organism. On the one hand, there is knowledge of the food's nutritional value, which refers to major and minor elements.

PDF 531 KB
Trace Metals in Waters by GFAAS, in Accordance with U.S. EPA and Health Canada Requirements

Precise and accurate measurements at the regulated levels are an important factor for assuring safe drinking water. U.S. EPA Method 200.91 is the method cited by EPA, Health Canada, and the WHO for the use of graphite furnace atomic absorption spectroscopy (GFAAS). In evaluating a GFAAS system for d ...

PDF 289 KB

Brochure

A Complete Portfolio of Grain Testing Solutions

Grains, whether consumed whole or processed, have nutritional and functional requirements and must be safe for consumption, and the only way to ensure grain quality is through rigorous testing. That’s where PerkinElmer come in. Our easy-to-operate, integrated testing and analytical solutions encompa ...

PDF 4 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, and ...

PDF 3 MB
Meat and Seafood Testing Solutions

Food testing labs like yours are constantly challenged with accurately analyzing samples quickly and efficiently - all while striving to reduce costs due to market forces. Your commitment to ensuring meat and seafood are safe for consumption, as demand increases, is an uphill battle. Our commitment ...

PDF 6 MB
PinAAcle 500 Flame Atomic Absorption (AA) Spectrometer

Engineered to deliver an uncompromising level of performance at an unbeatable price, the PinAAcle™ 500 puts the industry’s most robust, reliable flame AA spectrometer within reach of even the most budget-conscious laboratories. It offers superior durability, longer life, lower maintenance costs, and ...

PDF 1 MB

Catalog

Atomic Spectroscopy Consumables Catalog

Download your complete PDF catalog containing all the consumables needed to keep your Atomic Absorption, ICP-OES, and ICP-MS instruments up and running.

PDF 11 MB

Data Sheet

PinAAcle™ 500 Flame AA Consumables Sell Sheet

All of the PerkinElmer consumables and supplies for your PerkinElmer PinAAcle 500 Flame AA.

PDF 499 KB

Ebook

Palm Oil Analysis. Complete lab solutions from upstream to downstream

Quality control-monitoring and testing are important in ensuring the quality of palm oil. The quality control parameters are used to judge the quality of palm oil products and it can be monitored and tested to ensure that the palm oil is not deliberately or accidentally adulterated.

PDF 11 MB

Flyer

High Quality and Performance in Atomic Absorption Grain Testing Ensemble Flyer

Consumers are exposed to low levels of heavy metals on a daily basis and long term exposure can have negative health impacts. Since the elements themselves are distributed unevenly throughout, for example, cereal grain, with the germ and the outer layers having the highest concentrations, analyzing ...

PDF 1 MB

Guide

Atomic Spectroscopy - A Guide to Selecting the Appropriate Technique and System

Atomic spectroscopy is a family of techniques for determining the elemental composition of an analyte by its electromagnetic or mass spectrum. Several analytical techniques are available: Atomic absorption (AA): flame and graphite furnace Inductively coupled plasma optical emission spectroscopy (ICP ...

PDF 3 MB
PinAAcle 500/900 AA Spectrometers - Preparing Your Lab

This document provides detailed instructions regarding the space, accessories and utilities required to operate PerkinElmer’s PinAAcle family of atomic absorption (AA) spectrometers (500 and 900 series) and other major AA accessories.

PDF 941 KB

Product Note

Syngistix for AA Express Software - Only Three Steps to Reliable Results

PerkinElmer’s Syngistix for AA Express software for the PinAAcle 900H AA spectrometer reduces complexity and speeds analysis time for an unmatched user experience.

PDF 1 MB

Regulatory Compliance Certification

Product Certificate - PinAAcle 500

Product Certificate for the Atomic Absorption Spectrometer, Model PinAAcle 500

PDF 97 KB

Technical Note

Analytical Quality with Genuine PerkinElmer Graphite Parts

The production of high-quality graphite components for atomic absorption spectroscopy requires stringent quality control. To ensure high quality and consistency, a specific high-density base graphite material has been developed for use with PerkinElmer graphite furnace systems.

PDF 245 KB

White Paper

The Determination of Metals in Non-Medical Face Masks

With the onset of the COVID-19 pandemic, the use of face masks by the general public has become a critical personal protective measure to minimize person-to-person transmission. While health care workers use medical or surgical masks, the general population uses non-medical, otherwise known as hygie ...

PDF 683 KB